The record
Record · Permits

QTS Data Center

2GC08872.noi
[verified]
Fields
facility_name
QTS Data Center
permit_no
2GC08872*AG
permit_action
notice of intent
applicant
QTS Realty Trust Inc.
application_no
OHC000006
public_notice_no
public_notice_date
comment_period_end
facility_address
8002 Mendon Road, Van Wert, OH 45891, Van Wert County, Pleasant and Ridge townships
discharge_address
receiving_water
Town Creek
stream_network
Town Creek -> Middle Creek -> Little Auglaize River -> Auglaize River -> Maumee River -> Lake Erie (HUC-8 04100007)
outfalls
note
Notice of Intent for coverage under Construction Site Stormwater General Permit OHC000006, electronically submitted 2026-07-21 by user 79558633 and certified under penalty of law by Tamir Mengesha, Project Manager. EPA form 4494 (Rev. 4/13), Application ID 288738011. Applicant QTS Realty Trust **Inc.**, 2470 Satellite Blvd NW, Duluth GA 30096 — note that this is neither the entity form nor the address the register carried from press coverage ("QTS Realty Trust, LLC", Overland Park KS); the applicant of record on the instrument is an Inc. at a Georgia address. Applicant and facility contact are the same person, Tamir Mengesha, at PreDev2026@Q.com. Coordinates 40.893356 / -84.5528 — the CAMPUS point, 3.66 km at bearing 44° (northeast) from the city centroid (40.8696 / -84.5829) that the site profile uses for its NASA POWER climatology and Atlas-14 design point; re-pointing those to the campus is a separate hydrology decision (#1403/#829), deliberately NOT taken here. Total land disturbance 792.0000 acres, on a campus the City zoned at 901.698 ac and the county deeded at 900.59 ac (#1401 / #1403), i.e. the disturbance is 87.8% of the zoned area (792 / 901.698) and 87.9% of the deeded acreage; the attached site map draws the limits of disturbance inside the property line and standing back from the watercourse in the northwest. Project window: start 2026-08-03, estimated completion 2030-08-03. Both dates are the applicant's own, and both differ from the press schedule the register carried (groundbreaking "Q4 2026", buildout "~2032"). Declares Individual NPDES 'NO', individual 401 WQC 'NO', Isolated Wetland 'NO', PTI 'YET_TO_APPLY', USACE nationwide permit 'YET_TO_APPLY'; SWP3 attachment '<None>'. The Facility/Map Attachment is named 'Site_Map_QTS_Van_Wert.pdf' and is committed beside this document as edoc-4209396.pdf. The stormwater outlet is Town Creek — the SAME water the City of Van Wert both withdraws its drinking water from and discharges its WWTP effluent to (2PD00006, #1406), which is a finding about the receiving water, not a relationship between the two permits.
⚠ Gaps in the record
  • CONSTRUCTION-PHASE ONLY. This instrument authorizes stormwater discharge from land disturbance and expires 2028-04-22. It states NOTHING about the campus's operating water use, cooling system, process discharge, or electrical load, and it must not be cited for any of them. It does not ground the facility's IT load, which remains the [reference] 500 MW press bracket (see src/watermark/sites/_profiles.py and data/extracted/van-wert/data-centers.md).
  • The NOI declares Ohio EPA PTI status 'YET_TO_APPLY' and USACE nationwide permit 'YET_TO_APPLY', certified under penalty of law on 2026-07-21. This is the corpus's ONLY instrument-grade statement that no air permit-to-install had been applied for; before it, the absence of a PTI was an unsuccessful-search negative. It dates the negative — it does not promise a future filing, and it says nothing about whether one is required.
  • Two townships are printed in the NOI's location block (Pleasant AND Ridge, on two County/Township lines) but Ohio EPA's approval letter for the same coverage names Pleasant only. Both are recorded as printed; the discrepancy is not resolved here. Recorded in `facility_address` as the NOI prints it, since the NOI is the applicant's own description of the site.
  • The NOI carries the FULL facility permit number 2GC08872*AG in its 'Existing NPDES Facility Permit Number' field even though it is the application, submitted 2026-07-21, nine days before the 2026-07-30 approval letter that grants the coverage. Recorded as printed — the same pattern as Sidney's 1GC10596 NOI.
  • Receiving water is printed as 'Town Creek' with no river mile. The downstream network below is NOT from this document — the NOI names only the receiving stream. It is carried from the committed Van Wert hydrology, which traces to a primary source: the 2PD00006 fact sheet prints "Subsequent Stream Network: Middle Creek, Little Auglaize River, Auglaize River, Maumee River, Lake Erie" (2PD00006.fs.npdes.yaml), and Town Creek reaches Middle Creek by combining with Maddox Creek (data/extracted/van-wert/water-watch.yaml). MIDDLE CREEK IS NOT OPTIONAL in that chain — an earlier register line omitted it and was corrected; do not drop it again.
Where it connects
oepa/van-wert/2GC08872.noi.npdes.yaml · · oepa