Watermark.
Sidney
Switch site 38 sites · 11 basins 8 open

Each site is one Watermark investigation. The page color says what opens; the campus line is the build on the ground — two different clocks.

MAU Maumee Basin 9 sites
2MI The Two Miamis 9 sites
SE Southeastern Basins 12 sites
NE Northeast Basins 8 sites
The page — what opens on Watermark Open · Draftfull record Queued · Watchingpreview page Restrictedrequest access
The campus — the build on the ground Investigating Confirmed Under construction Operational
All 38 sites — the network index →
Live

Hydrology — water balance

Each scenario screens the Great Miami River's low-flow capacity against the campus's consumptive cooling draw: live flow minus consumptive loss against the 7Q10 design low flow, and the assimilative headroom that remains. Live gauge and permit figures are grounded; scenario draws are labelled assumptions.

Cooling method not on the record

A facility is documented here, but no record discloses how it rejects heat. The consumptive water figure is therefore a range across candidate cooling archetypes — 0 MGD (closed-loop dry) to 4 MGD (evaporative tower) — not an estimate. A single headline would fabricate the site's most load-bearing number; the section stays locked until the method is disclosed.

Have a water contract, wastewater permit, or cooling-plant spec? Submit the disclosure →

baseline

Current municipal loop, no data-center cooling draw.

Cooling model: no cooling-water load

Cooling demand: 0 MGD · consumptive fraction 0 fraction

Consumptive lossmodeled
0cfs
0 MGD x 0 consumptive (scenario baseline)
[inference]
Great Miami River 7Q10grounded
24cfs
Ohio EPA "Fact Sheet for NPDES Permit Renewal, City of Sidney WWTP, 2022" (permit 1PD00009*SD, application OH0027421), Table 14 "Instream Conditions and Discharger Flow", printed p.32 — GMR above Sidney, 7Q10 annual 24.0 cfs, USGS gage #03261500, 1927-2021 data. Read from the source PDF text layer (data/documents/oepa/sidney/1PD00009.c43b66fd.pdf, 0-based page 80), digits clean; structured read at data/extracted/oepa/sidney/1PD00009.npdes.yaml.
[verified]
Binding dilutiongrounded
2.22:1
Sidney WWTP → Great Miami River (Sidney WWTP outfall, RM 128.68)
[verified]

Assimilative screen · 0 of 1 receiving reaches fail the dilution band at design low flow (Sidney WWTP chronic 2.22:1, acute 1.79:1). The design flow is matched to the criterion type — chronic aquatic-life dilution at the 7Q10, acute at the sharper 1Q10; the effluent-credited ratio counts the permitted effluent already in the reach. A screening band, not a permit determination.