Watermark.
Bowling Green · Middleton Twp
Switch site 38 sites · 11 basins 8 open

Each site is one Watermark investigation. The page color says what opens; the campus line is the build on the ground — two different clocks.

MAU Maumee Basin 9 sites
2MI The Two Miamis 9 sites
SE Southeastern Basins 12 sites
NE Northeast Basins 8 sites
The page — what opens on Watermark Open · Draftfull record Queued · Watchingpreview page Restrictedrequest access
The campus — the build on the ground Investigating Confirmed Under construction Operational
All 38 sites — the network index →
Live
The record
Record · Permits

Apollo Power Generation Facility

P0139272.draft-pti
[verified]
Fields
agency
Ohio EPA
program
Air Permit-to-Install (Division of Air Pollution Control), OAC Chapter 3745-31
permit_no
P0139272
facility_id
0387022027
action
draft permit issued for public comment
action_date
2026-03-05
effective_date
expiration_date
permit_type
Initial Installation
applicant
Will-Power OH LLC - Apollo
applicant_address
2000 Commerce Dr, Pittsburgh, PA 15275
contact_name
Andy Woerner
project_name
Apollo Power Generation Facility
site_address
11902 Middleton Pike, Bowling Green, OH 43402 (Middleton Township, Wood County)
affected_resource
air
parcel_ids
comments_to
Andrea Moore, Permitting Section, Ohio EPA DAPC
note
Public-noticed in the Ohio EPA Weekly Review on 2026-03-05, opening the comment period that closed 2026-05-01 after an extension from 2026-04-15. The cover letter is explicit that "this draft action is not an authorization to begin construction or modification of your emissions unit(s)" — which is worth holding next to the separate, and lawful, pre-permit site-preparation allowance under OAC 3745-31-33 that the completeness letter conveyed in December.
⚠ Gaps in the record
  • SUPERSEDED — this is the draft, not the instrument. The final PTI issued 2026-06-02 and is transcribed at data/extracted/oepa/bowling-green/P0139272.pti.yaml. Cite the draft only for what it uniquely carries: the Permit Strategy Write-Up and its controlled-PTE table, and the two write-up defects recorded below.
  • THIS PDF IS SCANNED, NOT DIGITALLY GENERATED, AND ITS TEXT LAYER IS OCR. It renders "Yes" as "Ycs", "CH2O" as "CHZO", "SO2" as "S02" and "PM2.5" as "PM2 , 5". Figures quoted from it were checked against the same numbers as reprinted in Ohio EPA's hearing deck and in the final permit's Response 21, and the facility-ID defect below was confirmed by rendering the page image rather than trusting the OCR. Do not lift a digit from this file's text layer without a second source.
Where it connects
oepa/bowling-green/P0139272.draft-pti.yaml · · oepa